Researchers develop novel device to improve performance of underactive bladders
Individuals with an underactive bladder, for example following a spinal cord injury, often cannot sense bladder fullness or are unable to empty the bladder completely. This distressing symptom can seriously affect one’s quality of life. A dysfunctional bladder may also lead to medical complications such as urinary tract infection, as well as physical discomfort and potential for personal embarrassment.
Dr. Faezeh Arab Hassani, a researcher from the National University of Singapore (NUS), has recently invented a device that can monitor bladder volume in real time and effectively empty the bladder. This innovation may open up a new treatment option for patients with underactive bladders in the near future.
Dr. Arab Hassani worked closely with researchers from the NUS Department of Electrical Engineering and Computer Engineering, the NUS Department of Biomedical Engineering, as well as lead collaborator Professor Takao Someya and his research team at the University of Tokyo, and took more than a year to develop the novel bladder system. This breakthrough was first reported in the journal Science Advances on 1 May 2020.
Soft solution for a weak bladder
Among patients who have some form of spinal cord injury, about 80 percent of them suffer from some degree of bladder dysfunction. There is currently no cure for the underactive bladder condition, and while some implantable treatment options are available, they can only sense the fullness of the bladder and only empty it up to 43 percent.
“To help these patients, what clinicians need is an integrated bladder system that achieves both volume sensing capability and high voiding efficiency. Given that the urinary bladder is unique among human organs as it undergoes large volume changes during the storage and urination phases, the device requires careful compatibility considerations to avoid interference with the extreme volume changes of the bladder,” said Professor Nitish Thakor, who supervised the research.
Dr. Arab Hassani’s novel system comprises a sensor integrated with an actuator. The soft and thin sensor monitors the bladder volume continuously while the actuator is equipped with strong emptying force to clear the bladder. The actuator contains a shape memory alloy (SMA) spring, which keeps the sensor in contact with the surface of the bladder at all times for precise volume detection.
Experiments by the team showed that in addition to the real-time volume sensing capability, the device can also effectively empty between 70 to 100 percent of the bladder. “This is a significant achievement as its performance is comparable to the efficiency of intermittent catheterisation treatment currently being used, which has many shortcomings,” shared Dr. Arab Hassani, the first author of this study. “We need a soft but efficient device to help a weak bladder.”
Improvements and potential applications
Moving forward, the NUS research team is working to improve the functionality of the device, and looking into making the system wireless for ease of use and movement.
“The bladder system can be adjusted to the user’s bladder size to ensure optimal operation,” suggested Dr. Arab Hassani. “The ideal scenario would be to integrate the device with a mobile application, which can retrieve and process the sensor data to allow the user to trigger voiding at will.”
The team’s advances in soft materials and their fabrication techniques also hold other potential applications in the medical field.
Source: Read Full Article